MODEL | NASN2460-1P | NASN4850-1P | |
Environmental | Operating temperature | -40°C ~ 55°C | |
Storage temperature | -40°C ~ 70°C | ||
Relative humidity | 5%~95%RH(40±2ºC,no condensation) | ||
Atmospheric pressure | 62kPa~106kPa | ||
Altitude | ≤ 2000m (derating is necessary above 2,000m) | ||
AC Input | AC input system | L+N+PE/220Vac | L1+L2+L3+N/380Vac |
Input voltage range | 90VAC ~ 290VAC | 323-437VAC | |
Input AC voltage frequency | 45Hz ~ 65Hz | ||
THD | <5% (@230Vac,full load) | ||
Power factor | ≥ 0.99 | ||
DC Output | Rated output voltage | 24VDC | 48VDC |
Adjustable output voltage | 20VDC-30VDC continuously adjustable | 40VDC-60VDC continuously adjustable | |
System output current | 60A per module*(1~20) | 50A per module*(1~20) | |
System load regulation | ≤±0.5% | ||
System voltage | ≤±0.5% | ||
System stability | ≤±0.5% | ||
Efficiency | ≥ 93.2% | ||
Current sharing | module current sharing not more than ±5% | ||
Weighted noise | ≤ 2mV (300Hz ~ 3400Hz) | ||
Output distribution | MCB optional | ||
Rectifier module unit | Rectifier hot-swap | Hot-swap available.not influencing system operation | |
Rectifier indication | with operation.alarm.and fault indicators | ||
Soft start time | 3s-10s | ||
Installation method | support swappable | ||
rectifier fault influence | Not influencing the set parameters of rectifier when rectifier at fault | ||
Monitor module unit | Remote monitoring | With remote metering & remote control & remote signaling functions. providing standard RS485&TCP/IP Interface and 6 sets of the dry contact output port & Battery Temp.Sensor | |
Language | Default: English | ||
Remote control | rectifier start and close.battery test. equalize and float charging ,DIN /DO configuration and so on | ||
Alarm functions | With AC over voltage/under voltage.DC voltage over/under.module Communication fault and over temperature alarm,Battery remove,Surge and so on | ||
SAFTEY | Insulation resistance | Testing voltage 500VDC, Insulation Resistance ≥10M (normal atmospheric pressure, normal temperature, relative humidity <90%, no condensation) | |
Insulation strength | Input to output: 3500VDC @1min&leak current ≤10mA Input to enclosures: 3500VDC @1min&leak current ≤10mA Output to enclosures:750VDC @1min&leak current ≤10mA |
||
System leak current | ≤3.5mA(230Vac input) | ||
Grounding performance requirements | The system with operating ground and protection ground.with clear mark.the resistance between the enclosures of distribution and all palpable metal components and grounding nut is not more than 0.1Ω | ||
AC lightning protection | The equipment AC side can bear simulated lightning impulse Current of waveform 8/20μS and rated amplitude 40kA.(Optional) |
||
Noise | ≤55dB (A) (measured at 1m distance from the equipment) | ||
MTBF | ≥ 100000 hours |