Lithium High Frequency Online Tower UPS

Product Details
Customization: Available
Output Type: Single
Warranty: 1 Year
Still deciding? Get samples of US$ 500/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
12
Year of Establishment
2015-01-06
  • Lithium High Frequency Online Tower UPS
  • Lithium High Frequency Online Tower UPS
  • Lithium High Frequency Online Tower UPS
  • Lithium High Frequency Online Tower UPS
  • Lithium High Frequency Online Tower UPS
  • Lithium High Frequency Online Tower UPS
Find Similar Products

Basic Info.

Model NO.
high frequency UPS
Input Voltage
90~300VAC
Connection Mode
Series Switching Power Supply
Starting Mode
Self-excited Switching Power Supply
Voltage Regulating Mode
Frequency Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
One-way Transmission
Modulation System
PWM
Certification
CE
Brand
Nasn
Input
Single Phase 220V
Output
208/220/230/240VAC
Output Current
4A
Protection
High Tempeturer Protection
Factory
Factory Supply
Used for
48V Battery or 48V Load
LCD Screen
Yes
Support
OEM/ODM
Package
Carton Box
Efficiency
97%
Feature
Soft Start
AC Input Voltage Range
90~300VAC
Communication
RS232, RS485, Snmp
Plug and Play
Hot Swappable
Mode
Switch Mode Power Supply
Transport Package
Carton
Specification
190*323*420MM
Trademark
NASN
Origin
China
HS Code
8504402000
Production Capacity
100PCS/Month

Packaging & Delivery

Package Size
19.00cm * 32.00cm * 42.00cm
Package Gross Weight
10.000kg

Product Description

Lithium High Frequency Online Tower UPS 
 

Online UPS Summary

An Online UPS output is independent of voltage and frequency variations of the mains.

  • Offers the highest level of critical load protection as the load is supplied with closely regulated power at all times

  • Has a load break of less than 5ms when transferring between inverter and bypass

  •  

  • Is totally transparent to the load in the case of a mains failure

  • Is the most expensive capital cost of UPS systems

  • Has a higher running cost than other types of system, as the rectifier and inverter are permanently on load.




Features:

1.The overall efficiency is as high as 98%; Provide ECO mode, achieving efficiency of over 99% and reducing power loss of UPS. 2. Design to meet the requirements of the power grid and provide a wide input voltage range of 210VAC~475VAC. Suitable for harsh power grid environments. The excellent input frequency range enables UPS to adapt to different power supply devices such as generators.
3. IGBT frequency modulation intelligent rectification and inversion technology, with an input power factor of up to 0.99 and input current harmonics as low as 3%; The output voltage and current performance are more excellent.
4. Powerful overload capacity: 110-125% load can operate normally for 10 minutes; 125-150% load can operate


Applications:
Vehicle and shipboard equipment: Railway station, transportation equipment, etc.
Industrial equipment: solar power, wind power, gas discharge lamps, etc.
Office equipment: computer, printer, copy, scanner, etc.
Kitchen appliances: microwave oven, induction cooker, rice cooker, etc.
Household electrical equipment: electric fans, vacuum cleaners, lighting fixtures, etc.
Datasheet: 
 

Model

HSS1101LT

HSS1101LST

HSS1102LT

HSS1102LST

HSS1103LT

HSS1103LST

Capacity

VA/W

1kVA/900W

2kVA/1.8kW

3kVA/2.7kW

Topology

Double Conversion Online UPS

Phase

Single Phase Input Single Phase Output

Mains Input

Wiring

L/N+PE

 

Rated Voltage

208/220/230/240VAC

 

Voltage Range

90~300VAC

 

Frequency Range

40Hz-70Hz

 

Input Power Factor

≥0.99

AC Output

Wiring

L/N+PE

 

Output Voltage

208/220/230/240VAC

 

Voltage Regulation

±1%

 

Output Frequency

50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)

 

Waveform

Sine Wave

 

Distortion

(THDV%)

<2%(Linear Load)

   

<8%(None-Linear Load)

 

Over load capability

100%~105% continuous.

60Sec.@105%~130% Rated Load

10Sec.@130%~150% Rated Load

0.3Sec.@>150%Rated Load

Efficiency

Line Mode

90%

91%

92%

 

Battery Mode

87%

88%

89%

Battery

&

Charger

Rated Battery Voltage

48/51.2VDC (default for 15/16cell of LiFePO4 )

 

Battery Capacity

615WH

External Battery Depends

920WH

External Battery Depends

1250WH

External Battery Depends

 

Backup Time

>30mins @ Full Load

 

>20mins @ Full Load

 

>20mins @ Full Load

 
 

Backup Time 2

(External Battery Module)

51.2V30AH-90mins

51.2V50AH-150mins

51.2V100AH-300mins

@ Full Load

51.2V30AH-45mins

51.2V50AH-75mins

51.2V100AH-150mins

@ Full Load

51.2V30AH-30mins

51.2V50AH-50mins

51.2V100AH-100mins

@ Full Load

 

Charging Current

Standard Model with Internal Battery:4A

Long Backup Time Model :4A / 8A(Optional)/ 16A(Optional)

 

Charging Voltage

56.8V(default for 16cell of LiFePO4 ) / Customized according to battery request

 

Charger Behavior &

Protection

CC. CV. Floating. Turn-Off 4 states

3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface

Physical

Chassis Style

RACK  / Tower   (separated)

 

Rack Dimension

1K: 438x88(2U)X400mm

1KS: 438x88(2U)X400mm

2K: 438x88(2U)X500mm

2KS:438x88(2U)X400mm

3K: 438x88(2U)X650mm

3KS:438x88(2U)X400mm

 

Tower Dimension

1KS~3KS: 190×318×368mm

  1K/2K/3K:190×323×420MM

 

Weight(Tower)

10.8kg

7.0kg

16.5kg

7.3kg

18.0kg

7.9kg

 

Weight(Rack)

12.5kg

6.5kg

21.6kg

6.8kg

24.5kg

8.2kg

HMI

LED DISPLAY

Mains / battery status, Load level, battery level, Operation Mode

 

LCD DISPLAY with LED indicator

Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status

 

Standards

COMMUNICATION

1. RS232 PORT/USB Card (not HID)

2. Dry Contact Interface for BMS control

3. ModBUS For BMS interface

 

Optional Extension Card

4. Network Card:  Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page,  PC Monitor Software , Support Server / NAS shutdown

5. RS485-Modbus Card,  LAN(TCP IP)-ModBUS Card,

6. Mini AS400 Relay Card

Operating Environment

Endurance

Temperature range

-10~50oC

 

Relative Humidity

0-98%(Non-condensing)

 

Acoustics Noise

<55dB @ 1 meters

 

 

Model

LSS1101LT

LSS1101LST

LSS1102LT

LSS1102LST

LSS1103LT

LSS1103LST

Capacity

VA/W

1kVA/900W

2kVA/1.8kW

3kVA/2.7kW

Topology

Double Conversion Online UPS

Phase

Single Phase Input Single Phase Output

Mains Input

Wiring

1 phase 3wires ( L / N+PE)

 

Rated Voltage

110/115/120/127VAC

 

Voltage Range

Line-Neutral: 60~145VAC

 

Frequency Range

40Hz~70Hz

 

Input Power Factor

≥0.99

AC Output

Wiring

L/N+PE

 

Output Voltage

110/115/120/127VAC

 

Voltage Regulation

±1%

 

Output Frequency

50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)

 

Waveform

Sine Wave

 

Distortion

(THDV%)

<2%(Linear Load)

   

<8%(None-Linear Load)

 

Over load capability

1Min@105%~125%Rated Load

30Sec.@125%~150%Rated Load

0.5Sec.@>150%Rated Load

Efficiency

AC/AC Mode

88%

89%

90%

 

DC/AC Mode

86%

87%

88%

Battery

&

Charger

Rated Battery Voltage

48/51.2VDC (default for 15/16cell of LiFePO4 )

 

Battery Capacity

615WH

External Battery Depends

920WH

External Battery Depends

1250WH

External Battery Depends

 

Backup Time

>30mins @ Full Load

 

>20mins @ Full Load

 

>20mins @ Full Load

 
 

Backup Time 2

(External Battery Module)

51.2V30AH-90mins

51.2V50AH-150mins

51.2V100AH-300mins

@ Full Load

51.2V30AH-45mins

51.2V50AH-75mins

51.2V100AH-150mins

@ Full Load

51.2V30AH-30mins

51.2V50AH-50mins

51.2V100AH-100mins

@ Full Load

 

Charging Current

Standard Model with Internal Battery:4A

Long Backup Time Model :4A / 8A(Optional)/ 16A(Optional)

 

Charging Voltage

56.5V(default for 16cell of LiFePO4 ) / Customized according to battery request

 

Charger Behavior &

Protection

CC. CV. Floating. Turn-Off 4 states

3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface

Physical

Chassis Style

RACK  / Tower   (separated)

 

Rack Dimension

1K: 438x88(2U)X400mm

1KS: 438x88(2U)X400mm

2K: 438x88(2U)X500mm

2KS:438x88(2U)X400mm

3K: 438x88(2U)X650mm

3KS:438x88(2U)X400mm

 

Tower Dimension

1KS~3KS: 190×323×368MM

  1K~3K:190×323×420MM

 

Weight(Tower)

10.8kg

5.0kg

16.5kg

5.5kg

18.0kg

7.9kg

 

Weight(Rack)

12.5kg

6.5kg

21.6kg

6.8kg

24.5kg

8.2kg

HMI

LED DISPLAY

Mains / battery status, Load level, battery level, Operation Mode

 

LCD DISPLAY with LED indicator

Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status

 

Standards

COMMUNICATION

1. RS232 PORT/USB Card (not HID)

2. Dry Contact Interface for BMS control

3. ModBUS For BMS interface

 

Optional Extension Card

4. Network Card:  Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page,  PC Monitor Software , Support Server / NAS shutdown

5. RS485-Modbus Card,  LAN(TCP IP)-ModBUS Card,

6. Mini AS400 Relay Card

Operating Environment

Endurance

Temperature range

-10~50oC

 

Relative Humidity

0-98%(Non-condensing)

 

Acoustics Noise

<55dB @ 1 meters

 



More details:

Lithium High Frequency Online Tower UPSLithium High Frequency Online Tower UPS
The SMPS based CONVERTER should be based on High Frequency (20 KHz and above)
Switch Mode techniques.
Resettable Fuses shall be provided, wherever appropriate, to protect the module against failure
of control / sensing circuit.
The design shall have suitable time delay / hysteresis to avoid hunting during switching ON and
OFF of the system. The module shall disconnect at 150V and reconnect at 170V AC.
Switching ON and OFF the fan shall be temperature controlled. In case of fan failure the module
shall have automatic protection to switch off the module above 70 deg centigrade and restore
automatically with reduction in temperature. It shall not cause any fire hazard. The fan shall also
be protected against short circuit by providing a fuse.
The CONVERTER modules shall have forced cooling and only DC fan shall be used.

DC Output Characteristics
 
The module shall be capable of operating in "Auto Float cum-Boost charger" mode. It shall be
programmed to operate as a float rectifier or a Boost charger depending on the condition of the
battery
 
Auto Float Mode
 
Float voltage of each rectifier module shall be set as given below:
Normal Float & Boost voltage for VRLA battery is 2.25V and 2.3V/Cell respectively.
For conventional battery it shall be 2.15V and 2.42V/cell, respectively.
For 110V/20Amp charger 55cells of 2V each will be used and for 48V/25A charger 24 cells of 2V
each will be used.
The module should have a range from 2.0 - 2.3V/cell in float mode & 2.2 - 2.5V/cell in boost
mode to meet the requirement of VRLA as well as conventional batteries.
The DC output voltage shall be maintained within ± 1% of the half load pre-set voltage in the
range 25% load to full load when measured at the output terminals over the full specified input
range.

Auto Boost Charge Mode
 
In auto boost charge mode, CONVERTER shall supply battery and equipment current till
terminal voltage reaches 2.3V (VRLA battery) /2.42V (Low Maintenance battery) per cell.and
shall change over to Auto Float mode after a defined delay of 0, 1, 2, 4 hours adjustable, to be
set as per battery manufacturer's specification.
 
Efficiency
The efficiency and Power factor of the CONVERTER in auto float and auto boost mode shall be
as follows:
Nominal input - 150-275V
Output - Full Load, Efficiency > 90% and Power factor >0.95 to unity
And for
Nominal input - 150-275V
Output - 25% to 100%, Efficiency > 85% and Power factor >0.9
Note: Active power factor correction circuit shall be adopted.
 
Total Harmonic Distortion
The total line harmonic voltage distortion shall not be more than 10%.
The total current harmonic distortion contributed by CONVERTER at the input shall not exceed
10% for all input condition and load 50% to 100% of the rated capacity.
 
Soft Start Feature
Slow start circuitry shall be employed such that CONVERTER module output voltage shall reach
its nominal value slowly within 10 to 20 seconds, eliminating all starting surges.
The maximum instantaneous current during start up shall not exceed the peak value of the
rectifier-input current at full load at the lowest input voltage specified.
 
Voltage Overshoot/Undershoot (with battery disconnected)
The CONVERTER modules shall be designed to minimize output voltage overshoot /
undershoot such that when they are switched ON, the DC output voltage shall be limited to ± 5%
of the set voltage and return to its steady state within 20 millisecond for any load of 25% to
100%.
The DC output voltage overshoot for a step change in AC mains from 150V to 275V shall not
cause shut down of CONVERTER module and the voltage overshoot shall be limited to ±5% of
its set voltage and return to steady state within 20ms.
The modules shall be designed such that a step load change of 25% to 100% or vice- versa
shall not result in DC output voltage overshoot/undershoot of not more than ±5% of the set value
and return to steady state value within 10 millisecond without resulting the unit to trip.
 
Parallel Operation
The CONVERTER modules shall be suitable for operating in parallel on active load sharing
basis with one or more modules of same type, make and rating.
The current sharing shall be within ± 10% of the individual capacity of each CONVERTER in the
system when loaded between 50 to 100% of its rated capacity.
 
Alarms & Indication of CONVERTER
The following indications, controls & measuring points shall be provided on the front panel of
CONVERTER
 
a) CONVERTER on Auto Float mode FLOAT Green
b) CONVERTER on Boost Charge mode BOOST Green
c) Mains available MAINS Amber
 
Alarm Indication with LED:
a) Rectifier module over voltage OVER VOLTAGE Red
b) Rectifier module under-voltage UNDER VOLTAGE Red
c) DC output fail OUTPUT FAIL Red
d) CONVERTER Overload/ short circuit OVERLOAD/ SHORT CIRCUIT Red
e) Fan fail FAN FAIL Red
Note: "Provision shall be made for stopping the audio alarm with a non-locking push button.
a) Float voltage adjustment (float)
b) Boost voltage adjustment (boost)
c) Overload current setting (OL)
d) Voltage monitoring point suitable for measurement by standard multimeter.

Other Popular
 

 

Rack Mounted 220VDC Rectifier with Parallel Charging Converter

Switch Mode Power Supply 110VDC Rectifier System

Telecom DC-AC Inverters 48V DC

off Grid Inverter Telecom Rack-Mounted Telecom Inverters

Utility Power Inverter 110VDC to 220VDC Power Inverter

Industrial Rectifier Battery Charger

3.5′ ′ Screen 220VDC Rectifier System From Manufacturer

Telecommunications Battery Rectifier 24V Base Station DC Power Charger

Lithium High Frequency Online Tower UPS
Lithium High Frequency Online Tower UPS
Lithium High Frequency Online Tower UPS
Lithium High Frequency Online Tower UPS
Lithium High Frequency Online Tower UPS
Lithium High Frequency Online Tower UPS
FAQ

Q1: What kind of EV Charger do you have?AC and DC charger with connectors Type2, CCS1/CCS2, CHAdeMO, GB/T, etc.

Q2: Do you provide customized product?
We provide OEM and ODM services for clients.

Q3: What is the delivery time of EV charger?

About 4-6 weeks.
Q4: What about your warranty of EV Charger?
Generally 2 years. Our warranty period depends on customer's requirements and we always put customer's need as priority.

Q5:How do you package it ?
A:We pack in cartons.

Q6:what's the MOQ?
A:For LOGO, color or other special requirements, a minimum of 20 is required. If you do not have these requirements you can buy
directly, we will ship within 3-10 days.

Q7:Can you produce according to the samples?
A:Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.

Q8:Do you test all your goods before delivery?
A:Yes, we have 100% test before delivery.

Q9:What is your terms of delivery?
A:EXW, FOB, CFR, CIF, DDU.

Q10:What is your terms of payment?
A:We accept all methods of payment: paypal, T/T, credit card, West Union... Please contact us for more details.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier